U.S. Code of Federal Regulations
Regulations most recently checked for updates: Aug 28, 2025
When permanent splices in trailing cables are made, they shall be:
(a) Mechanically strong with adequate electrical conductivity and flexibility;
(b) Effectively insulated and sealed so as to exclude moisture; and
(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.
(d) Made using splice kits accepted or approved by MSHA as flame resistant.